Install The Outdoor Unit; Connecting The Piping - Panasonic CS-A281 KR Manual

Hide thumbs Also See for CS-A281 KR:
Table of Contents

Advertisement

1. When installing two air conditioners in one room, each air
conditioner can be synchronized to the remote controller.
2. In order to operate separately, open the rear cover of one of the
remote controller and set the switch to "B".
3. Also, set the remote control No. switch to "B" in the
corresponding indoor unit.
(The switch is located in the control box-sub. of the indoor unit.)
10.3. OUTDOOR UNIT
10.3.1. SELECT THE BEST LOCATION / (Refer to "Select the best location"
section)

10.3.2. INSTALL THE OUTDOOR UNIT

- After selecting the best location, start installation according to
Indoor/Outdoor Unit Installation Diagram.
1. Fix the unit on concrete or rigid frame firmly and horizontally by
bolt nut. (ø10 mm).
2. When installing at roof, please consider strong wind and
earthquake. Please fasten the installation stand firmly with bolt or
nails.

10.3.3. CONNECTING THE PIPING

Connect Piping to Indoor
Please make flare after inserting flare nut (locate at joint portion of tube assembly) onto the
copper pipe.
(In case of using long piping)
Connect the piping
- Align the center of piping and sufficiently tighten the flare nut with
fingers.