Applicable: Flaring piping kit CZ-52F
INDOOR UNIT
- There should not be any heat source or steam near the unit.
- There should not be any obstacles blocking the air circulation.
- A place where air circulation in the room is good.
- A place where air drainage can be easily done.
- A place where noise prevention is taken into consideration.
- Do not install the unit near the door way.
- Ensure the spaces indicated by arrows from the wall, ceiling, or
other obstacles.
- Indoor unit of this room air conditioner shall be installed on the
wall in a height of at least 2.5 m.
OUTDOOR UNIT
- If an awning is built over the unit to prevent direct sunlight or rain,
be careful that heat radiation from the condenser is not obstructed.
- There should not be any animal or plant which could be affected by
hot discharged air.
- Keep the spaces indicated by arrows from wall, ceiling, fence or
other obstacles.
PDF created with pdfFactory Pro trial version
SELECT THE BEST LOCATION
29