The left and right airflow direction louvers
can be adjusted manually.
1 There is no swinging while indoor fan is
stopped during Cooling and Soft Dry
operation.
2 In Heating operation, when the indoor heat
exchanger temperature rises to 38°C, the
airflow direction is changed from upper
limit to lower limit. When the indoor heat
exchanger temperature falls to 35°C, the air
flow direction is changed from lower limit
to upper limit.
- When the airflow direction set button is pressed, the automatic
airflow is released and the airflow direction louver move up and
down in the range shown in the diagram.
The louver can be stopped by releasing the button at the desired
louver position.
- When the remote control is used to stop the operation, the
discharge vent is closed with airflow direction louver.
The left and right airflow direction louvers can
be adjusted manually.
8.9. Delay ON Timer Control
- When the Delayed ON Timer is set by using the remote control, the
unit will start operate slightly before the set time, so that the room
will reach nearly to the set temperature by the desired time.