When you press the SLEEP Mode, the following movement will start to avoid overheating.
- The fan speed refer to Indoor Fan Motor Control.
- The setting temperature will be risen by 2°C at the start of
operation and by 3°C one hour later.
- The operation will stop after 8 hours.
- When using together with the Timer, the ON-Timer has priority.
8.6. Auto Restart Control
- If there is a power failure, operation will be automatically restarted
when the power is resumed.
It will start with previous operation mode and airflow direction.
(Time Delay Safety Control is valid)
- Auto Restart Control is not available when Timer or Sleep Mode is
set.
- This control can be omitted by cutting the jumper wire J2. (Refer
Circuit Diagram)
8.7. Indoor Fan Speed Control
- Auto Fan Speed Control
When set to Auto Fan Speed, the fan speed is adjusted between
maximum and minimum setting as shown in the table.
- Manual Fan Speed Control