4. OPERATION
(b) Using the input signals for setting
Set the pulse generator multiplication 1 (TP0) and pulse generator multiplication 2 (TP1) to the
input signals in "Device setting" on the Servo Configuration Software (refer to Chapter 6).
Pulse Generator Multiplication 2
Note. 0: Open across TP1/TP0-SG
1: Shorted across TP1/TP0-SG
(4) Operation
Turn the manual pulse generator to rotate the servo motor. For the rotation direction of servo motor,
refer to (2) in this section.
Downloaded from
ManualsNet.com
Pulse Generator Multiplication 1
(across TP1)
0
0
1
1
search engine
Multiplication Ratio of Servo Motor
Rotation to Manual Pulse Generator
(across TP0)
0
Parameter No.1 setting valid
1
0
1
4 - 20
Moving Distance
Rotation
1 time
10 times
10[ m]
100 times
100[ m]
1[ m]