Installing Fluid Metering Assembly; Installing The Fluid Metering Assembly - Graco PrecisionFlo XL Manual

Metering modules
Hide thumbs Also See for PrecisionFlo XL:
Table of Contents

Advertisement

Installing Fluid Metering Assembly

To install the fluid metering assembly hardware:
D Install the PrecisionFlo fluid metering assembly
D Ground the PrecisionFlo system
D Connect the PrecisionFlo fluid metering assembly
to the control assembly
D Connect fluid lines and cables

Installing the Fluid Metering Assembly

WARNING
ELECTROCUTION HAZARD
Installing and servicing this equipment
requires access to parts which could
cause an electric shock or other serious
injury. Have only qualified electricians access the
fluid metering assembly .
Preparing to Install the Assembly
Before installing the fluid metering assembly:
D See component manuals for specific data on com-
ponent requirements. Data presented here pertains
to the PrecisionFlo fluid metering assembly only.
D Have all system and subassembly documentation
available during installation.
D Be sure all accessories are adequately sized and
pressure-rated to meet the system's requirements.
D Use only the Graco PrecisionFlo fluid metering
assembly with the PrecisionFlo control assembly.
Installing the Assembly
WARNING
EQUIPMENT MISUSE HAZARD
The fluid metering assembly weighs
approximately 60 lbs and should never
be moved or lifted by one person. Use
adequate personnel and support devices when
mounting, moving or handling the control assembly
to prevent equipment damage or personal injury.
1. Select a location for the PrecisionFlo fluid metering
assembly. Keep the following in mind:
D
Allow sufficient space for installing and using
the equipment.
D
Make sure all fluid lines, cables and hoses
easily reach the components they will be
connected to.
D
Make sure the fluid metering assembly allows
the robot to move freely along all axes.
D
Make sure the fluid metering assembly pro-
vides easy access for servicing its compo-
nents.
2. Locate and secure the PrecisionFlo XL fluid meter-
ing assembly to the robot (or other mounting
surface) with four 3/8 in. bolts through the 0.42 in.
diameter holes in the base plate. See the mounting
dimensions for the electric regulator system in Fig.
5.
Measurements, inches (mm)
A
B
C
D
C
D
0.42 in. diameter
holes (typical)
Models 233652, 233653, 233654, 233672, 233673
Fig. 5
17.0 (432)
16.0 (407)
15.0 (381)
14.0 (356)
A
B
309375
9