Adjusting the Shock Sensor

1.
Increase sensitivity by turning the adjustment dial clockwise.
2.
Decrease sensitivity by turning the adjustment dial counter clockwise.

Testing the Shock Sensor

Arm the system and wait 6 seconds for the zone to stabilize, then firmly strike the
vehicles bumper.

Chirp Delete - User Accessible

System ARM/DISARM chirps can be toggled ON or OFF without entering the
programming feature banks.
1.
Turn the ignition ON then OFF.
2.
Press and release the valet/programming button 3 times. The system
will respond with 1 chirp for ON or 2 chirps for OFF.

Dome Light Delay / Theater Dimming

The system can be programed to delay arming after the lock button is pressed
(60 second max) for vehicles with a dome light delay or theater dimming feature.
Once programed the system will 'learn' the timing of the dome light delay and add 2
seconds before arming.
1.
Close all doors with ignition off.
2.
Using the transmitter press LOCK, UNLOCK, LOCK ,UNLOCK, LOCK ,
UNLOCK, LOCK. The LED will light solid to indicate the system has
entered DOME DELAY LEARN MODE.
3.
Immediately OPEN then CLOSE the door WITHOUT disarming the
system. The system will then monitor the door trigger wire. Once the
dome light turns off, the system will then add 2 seconds and then exit
the learning mode.
4. The LED will begin to flash indicating the system has exited the
learning mode and is now armed.