Panasonic SA-AK520E Service Manual page 60

Table of Contents

Advertisement

No.
Abnormal Items
1
REST SW abnormal
2
Transmission error between
CD servo LSI and micon
3
CLAMP SW abnormal
4
BOTTOM SW abnormal
5
POSITION SW abnormal
6
SW1 abnormal
7
SW2 abnormal
8
OPEN SW abnormal
12.3. Power Supply related error detection
No.
Abnormal Items
1
POWER AMP output
abnormal
13. Self-Diagnostic Function
13.1. Self-diagnostic display
This unit is equipped with a self-diagnostic display function which, if a problem occurs, will
display an error code corresponding to the problem.
Use this function when performing maintenance on the unit.
13.2. How to enter the Self-Diagnostic Function
Error
Method of Detection
Display
F15
Under normal operation (Self-Diagnostic Mode
inclusive), this error occurs when the REST SW
not detected within the specified time and shall
memorized.
F26
Under normal operation (Self-Diagnostic Mode
inclusive), this error occurs when the selection
to CD and SENSE='H' is detected and SENSE='L'
detected within a fail safe time (20ms) after system
command transmission was sent.
F16
Refer to CR20 control specification section 5-2
[ERROR CODE] table M-0A error is detected.
F17
Refer to CR20 control specification section 5-2
[ERROR CODE] table M-09 error is detected.
F27
Refer tp CR20 control specification section 5-2
[ERROR CODE] table M-05 ~ M-08 error is detected.
F28
Refer to CR20 control specification section 5-2
[ERROR CODE] table M-02 ~ M-08 error is detected.
F29
Refer to CR20 control specification section 5-2
[ERROR CODE] table M-02 ~ M-08 error is detected.
H15
Refer to CR20 control specification section 5-2
[ERROR CODE] table M-01 error is detected.
Error
Method of Detection
Display
F61
During normal operation, if DCDET 1/2 becomes
normal POWER OFF process shall not be executed,
PCNT shall be switched to 'L' immediately. GOODBYE
shall not be displayed and the error display F61
displayed instead.
2 seconds after the F61 display, ECONO shall be
'L' and FL display shall be turned off.
The error content shall be memorized when the
abnormality occurs and can be displayed in the
mecha self-diagnostic mode described later.
60

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sa-ak520ebSa-ak520eg

Table of Contents