GENERAL ACCESS AND EMPTYING HYDRAULIC CIRCUITS

2 .5 Emptying the primary circuit

1 Close the C.H. circuit flow and return cocks "M" (Figure 2.10).
N
Figure 2 .10
2 Remove the front and right panels of the boiler.
3 Loosen the central heating drain cock "O" (Figure 2.11) until
the boiler is completely emptied.
CLOSED
OPEN
O
Figure 2 .11
4 To make draining easier, lift the plug "P" of the automatic re-
lief valve in Figure 2.12.
Figure 2 .12
2 .6 Emptying the D .H .W . circuit
1 Close the D.H.W. inlet cock "N" (Figure 2.10).
2 Open one or more hot water taps until the boiler has been
M
P
completely emptied.