GENERAl ACCESS ANd EMPTyiNG HydRAuliC CiRCuiTS
figure 2.4
5 Remove the screws E and remove the service panel (Figure
2.5);
6 To gain access to the electronic regulation PCB remove the
screws F and remove the control panel lid (Figure 2.5);
f
E
figure 2.5

2.4 Access to the sealed chamber

G
G
figure 2.6
To gain access to the parts contained in the sealed chamber it is
necessary to remove the lid of the sealed chamber. For this pur-
pose, remove the front and side panels of the case, remove the
screws G as indicated in Figure 2.6 and remove the lid.
- 6 -

2.5 Emptying the primary circuit

1 Close the c.h. circuit flow and return cocks.
2 Remove the front and right panels of the boiler.
3 Open the drain tap I (Figure 2.7) until the boiler is completely
emptied.
4 Close drain tap again once the emptying has been complet-
ed.
f
figure 2.7

2.6 Emptying the d.h.w. circuit

5 Close the d.c.w. inlet cock;
6 Open one or more hot water taps until the boiler has been
completely emptied.