Cleaning - Biasi RINNOVA ADAPTIVE M300V.2025 SM Service Manual

Combi boiler
Table of Contents

Advertisement

5 .3 Cleaning

If there are deposits of dirt on the coil of the Condensing heat
exchanger, clean with a bristle paintbrush and remove the dust
with a hoover.
Warning: After cleaning or replacement as detailed
above, it is deemed necessary to undertake a com-
bustion analysis as detailed in chapter "11 .3 Adjust-
ment - Chimney Sweep Function" on page 31 sec-
tion "11 GAS VALVE" on page 31 .
O
Figure 5 .4
Caution:
After any periodical servicing or disturbance the combustion
chamber silicon seal "O" Figure 5.4 must be fully inspected and
replaced at the discretion of the service engineer.
After any disturbance to the chamber door seal the appliance
must undergo a full analytical combustion performance check.
Remove any limescale from the detection electrode
and replace it if worn .