Checks; Removal Of The Electronic Control P.c.b - Biasi RINNOVA ADAPTIVE M300V.2025 SM Service Manual

Combi boiler
Table of Contents

Advertisement

PARAMETER
Boiler model/type
Type of gas
User interface
Type of domestic hot water exchanger
Type of primary circuit control device
Type of D.H.W. flow control device
Maximum Temperature heating delivery
(°C)
Minimum heating delivery temperature
(°C)
Maximum heating output (%)
Re-ignition frequency in heating mode
(*10 sec.)
Adjusting the minimum pump speed
(%)
Pump post-circulation
Pump mode operation
Value of the external sensor K
Correct heating system pressure (*10
bar)
Maximum heating system pressure limit P16
∆T heating delivery/return due to
reduction of pump speed
Adjusting maximum domestic hot water
temperature
Adjusting minimum temperature of
domestic hot water
Minimum closing flow rate of the
D.H.W. flow switch (ON)
Minimum opening flow rate of the
D.H.W. flow switch (OFF)
Ignition delay in D.H.W. mode
Burner shut-off as a function of D.H.W.
temperature
Burner ignition as a function of D.H.W.
temperature
D.H.W. pre-heating mode
D.H.W. post-heating mode (at end
of D.H.W.) (01=M300V.2025 SM -
M300V.2530 SM, 02=M300V.3035 SM)
Adjusting output power in D.H.W. mode
(%)
Adjusting maximum D.H.W.
temperature in anti-legionella function
(°C) (only for boilers with a sensor)
Anti-legionella function activation
frequency (days)
Reset (restores factory settings)
Chimney sweep
Adjusting the minimum power in
D.H.W. mode (%)
Regulation of the minimum power in
heating mode (%)
Maintenance intervals (months)
Antifreeze activation temperature
Antifreeze deactivation temperature
Antifreeze activation temperature with
external sensor
- 24 -
MAIN ELECTRONIC CONTROL/IGNITION P.C.B.
DIGIT
VALUES
P01
P02
P03
P04
P05
P06
P07
P08
P09
P10
P11
P12
P13
P14
P15
P17
P18
P19
P20
P21
P22
P23
P24
P25
P26
P27
P28
P29
P30
P31
P32
P33
P34
P35
P36
P37
PARAMETER
External relay operating mode 1
(0=OFF, 1=Zone by remote, 2=Alarm)
External relay operating mode 2
(0=OFF /TA2=OFF, 1=Zone heat. 2 /
TA2 active, 2= EVG ext / TA2 Active, 3=
Anomaly / TA2 Active, 4 =Remote filling
/ TA2 active)
Size shown on the display during
operation (0=T.CH or T.DHW, 1=only
T.CH, 2=only T.DHW, 3=CH pressure,
4=T.ext)
Messages display (0all, 1=boiler status
and errors, 2=boiler status only)
Not used
Not used
Not used
Not used
Not used
Not used
Not used
Not used
Not used
Not used
Chimney diaphragm
Fan speed at maximum
Fan speed at minimum
Ignition power
Gas valve management
Type of external sensor
Tab 9.1

9 .5 Checks

Check that the fuses are complete
If the Main electronic control/ignition p.c.b. does not supply any
device (pump, fan, etc.) check that the fuses 2 (Figure 9.2) are
complete.
If a fuse has blown replace it with one that has the same charac-
teristics after having identified the reason for failure.
Lock sequence
Start the boiler until the burner is ignited.
With the burner firing, interrupt the gas supply. The Main elec-
tronic control/ignition p.c.b. must carry out four complete ignition
cycles and then, after about 4 minutes, goes to lock-out state.
Switch off and on the electricity supply to the boiler, by means of
the fused spur isolation switch, the device must not unlock and
the burner must not turn on.
9 .6 Removal of the electronic control p .c .b
Warning: isolate the boiler from the mains electrici-
ty supply before removing any covering or compo-
nent .
When replacing the Main electronic control/ignition p .c .b .
all parameters must be correctly checked / adjusted accord-
ingly with the values noted in table in the installation manual
see chapter COMMISSIONING section: Setting record (for
information on parameters see also section "9 .4 Setting the
boiler control function modes" on page 23) .
DIGIT
VALUES
P38
P39
P40
P41
P42
––––––
P43
––––––
P44
––––––
P45
––––––
P46
––––––
P47
––––––
P48
––––––
P49
––––––
P50
––––––
P51
––––––
P52
P53
P54
P55
P56
P57