CONTROL PFT STEP
"INT COMM TEST FAIL"
"CTL MOT PWR ON FAIL"
"MON MOT PWR ON FAIL"
"HALL 1 FAIL"
"HALL 2 FAIL"
"HALL 3 FAIL"
"HALL 4 FAIL"
"HALL 5 FAIL"
"HALL 6 FAIL"
"CURR OFFST FAIL"
"SVO TYPE FAIL"
"CERT DATA
UNINSTALLED"
"STRAP CODE MISMATCH"

Table 4-4. Control Processor Normal Mode Faults

CONTROL FAULT
"GIA DIS FAULT"
"HOST DATA DIF"
"HOST DATA INV"
"SVO PWR INV"
"STRP CODE CHNG"
"MET STUCK SWTCH"
"MET STATUS DIF"
4.12.2.3 Downloading GIA and GSA Maintenance Logs
If additional assistance is needed troubleshooting autopilot faults, the Maintenance logs can be
downloaded to an SD card as a text file (.txt) and emailed to Garmin Aviation Product Support at
Avionics@Garmin.com. Please call Garmin Aviation Product Support before you send a Maintenance
Log to notify them you are sending it to prevent a delay in response. You may download multiple GIA
and GSA Maintenance Logs to the same file, however in your email to Garmin you must furnish the order
in which they were downloaded (i.e. GIA1, then GIA2, then SRVO PTCH MON, then SRVO PTCH
CTL, etc.).
1. Insert a FAT 32 formatted SD card into the top slot of the PFD before turning on the displays.
2. Power up PFD and MFD in the configuration mode.
G1000-Columbia 350/400 System Maintenance Manual
190-00577-03

Table 4-3. Control Processor PFT Faults

NOTES
This can sometimes be a result of a failure on the other
board, check faults on other processor
Check unit power and AP Disconnect power
Check unit power and AP Disconnect power
Check unit power and AP Disconnect power
Check unit power and AP Disconnect power
Check unit power and AP Disconnect power
Check unit power and AP Disconnect power
Check unit power and AP Disconnect power
Check unit power and AP Disconnect power
Check unit power and AP Disconnect power
Check unit power and AP Disconnect power
Upload the certification gain file to the Control board
Check the connector strap inputs to the unit
NOTES
Check the AP Disconnect power into the unit
Check the AHRS wiring to the system
Check the AHRS wiring to the system
Check unit power and AP Disconnect power
Check the connector strap inputs to the unit
Check the MET switch inputs into the system
Check the MET switch inputs into the system