Transportlayercontrol; Digitaliocontrol; Counterandtimercontrol - Omron STC-MBS322U3V Product Specifications And User's Manual

Usb3 vision monochrome / color cmos camera
Table of Contents

Advertisement

Name
PayloadSize
Name
LineSelector
LineMode
LineInverter
LineStatus
LineSource
UserOutputSelector
UserOutputValue
StrobeOutDelay
StrobeOutOnTime
TriggerOutDelay
TriggerOutOnTime
LineDeviceResetMode
LineDebounceTime
Name
CounterSelector
CounterEventSource
CounterEventActivation
CounterResetSource
CounterResetActivation
CounterReset
CounterValue
CounterValueAtReset
CounterDuration
CounterStatus
CounterTriggerSource
CounterTriggerActivation
STC-MBS322U3V / STC-MCS322U3V / STC-MBS510U3V / STC-MCS510U3V
Product Specifications and Use's Guide
Description
Provides the number of bytes transferred for each image or chunk on the stream
channel. This includes any end-of-line, end-of-frame statistics or other stamp data. This
is the total size of data payload for a data block.
Description
Selects the physical line (or pin) of the external device connector to configure.
Controls if the physical Line is used to Input or Output a signal.
Controls the inversion of the signal of the selected input or output Line.
Returns the current status of the selected input or output Line.
Selects which internal acquisition or I/O source signal to output on the selected Line.
LineMode must be Output.
Selects which bit of the User Output register will be set by UserOutputValue.
Sets the value of the bit selected by UserOutputSelector.
Delay of StrobeOut signal when LineSource is set to StrobeOut(us).
Duration of StrobeOut signal when LineSource is set to StrobeOut(us).
Delay of TriggerOut signal when LineSource is set to TriggerOut(us).
Duration of TriggerOut signal when LineSource is set to TriggerOut(us).
Sets the Line device reset mode.
Sets the value of the input line debouncer time.
Description
Selects which Counter to configure.
Select the events that will be the source to increment the Counter.
Selects the Activation mode Event Source signal.
Selects the signals that will be the source to reset the Counter.
Selects the Activation mode of the Counter Reset Source signal.
Does a software reset of the selected Counter and starts it. The counter starts
counting events immediately after the reset unless a Counter trigger is active.
CounterReset can be used to reset the Counter independently from the
CounterResetSource. To disable the counter temporarily, set CounterEventSource to
Off.
Reads or writes the current value of the selected Counter.
Reads the value of the selected Counter when it was reset by a trigger or by an
explicit CounterReset command.
Sets the duration (or number of events) before the CounterEnd event is generated.
Returns the current status of the Counter.
Selects the source to start the Counter.
Selects the activation mode of the trigger to start the Counter.
No.15S013-02
62/67