Flush mounting dimensions (mm)
For this type of mounting, you have to make
an additional cut at the edges of the recess
if you wish to install the hob flush with the
countertop.
A
B
min.
min.
50
460
L
X
730 ÷
800
750
900
840
1 = Electrical connection
76
Installation
C
D
min.
20÷60
750
Y
G
480 ÷
803
490
478 ÷
903
482
After laying the adhesive seal (A) on the
glass surface and after positioning and
securing the hob, fill the edges with
insulating silicone (B) and wipe away any
excess. In the event the hob needs to be
removed, cut the silicone using a cutter
before attempting to remove it (C).
5.6 Mounting
Over built-in oven unit
If installed on top of an oven, the
latter must be equipped with a
cooling fan.
The clearance between the hob and the
kitchen units or other built-in appliances
must be enough to ensure sufficient
ventilation and air discharge. If installed
above an oven, a space must be left
between the bottom of the hob and the top
E
of the appliance installed below.
min.
50
H
513
513
opens on bottom