Installing and Connecting the HP 600/610 External Power Supplies
Recommended Connection Topologies
EPS cables

Limitations

In the illustration above, the two switches connected to the HP 600 RPS/EPS
are limited to 204 W of power on each EPS port. If a switch tries to draw more
than 204 W of power from the HP 600 RPS/EPS, an over-current condition
occurs and the EPS port shuts down. To supply more than 204 W on one EPS
port, the other port must first be disconnected. The maximum power that can
be provided when only one EPS port is connected to a switch is 408 W.
2-18
RPS
12 V
7.5 A
50 V
16 A
RPS
12 V
7.5 A
50 V
16 A
Device Connected
R1
R2
R3
RPS 1
RPS 2
RPS 3
RPS 4
Power Status
HP ProCurve Switch 2650-PWR units
Line: 50/60 Hz.
100-240 V~ 7.5 A
Line: 50/60 Hz.
100-240 V~ 7.5 A
Device
R4
R5
R6
E1
E2
Connected
RPS 5
RPS 6
EPS 1
EPS 2
Power
Status
AC Power
HP 600 RPS/EPS