5. Connect to AC Power

Connect the AC power cord supplied with the HP 600 RPS/EPS or HP 610 EPS
to the power connector on the back of the unit, and then into a properly
grounded electrical outlet.
sconnect both the AC cord and EPS Backup power cables to completely remove power from the unit.
N o t e
The HP 600 RPS/EPS and HP 610 EPS do not have a power switch. They are
powered on when the power cord is connected to the unit and to a power
source. For safety, the power outlet should be located near the unit installa-
tion.
The HP 600 RPS/EPS automatically adjusts to any voltage between 100--240
volts and either 50 or 60 Hz, and the HP 610 EPS between 110--240 volts and
either 50 or 60 Hz. There are no voltage range settings required.
If your installation requires a different power cord than the one supplied with
the unit, be sure the cord is adequately sized for the unit's current require-
ments. In addition, be sure to use a power cord displaying the mark of the
safety agency that defines the regulations for power cords in your country.
The mark is your assurance that the power cord can be used safely with the
unit.
Installing and Connecting the HP 600/610 External Power Supplies
R5
R6
RPS 5
RPS 6
HP 600 RPS/EPS
Device
E1
E2
Connected
EPS 1
EPS 2
Power
Status
Connect the AC power cord to
HP 610 EPS
Line: 50/60 Hz
110
240 V~
11
6 A
Connect the AC power cord to
Installation Procedures
the power connector
the power connector
2-13