V Minimum
90 Elbow *
1/2 ft.*
1-1/2 ft.*
2-1/2 ft.*
3-1/2 ft.
4-1/2 ft.
H + H
V + H + H
H
2
Fire Risk.
• When using SLP-HRC-SS and SLP-HRC-ZC-SS
termination caps on top vented fi replaces, a one
foot minimum vertical vent section is required before
installing fi rst elbow.
• When using DVP-TB1 termination cap on top vented fi replaces,
a three foot minimum vertical vent section is required before
installing fi rst elbow.
Figure 7.5
Top Vent - Horizontal Termination
Venting with two 90º elbows
H
+ H
Maximum
1
2
SLF-550TR-IPI-E
1/2 ft.
152 mm
152 mm
1 ft.
305 mm
457 mm
2 ft.
610 mm
762 mm
4 ft.
1.2 m
1.1 m
6 ft.
1.8 m
1.4 m
14 ft.
4.3 m
MAX. =14 ft. (4.3 m)
1
MAX. = 40 ft. (12.2 m)
1
* See warning below
INSTALLED
HORIZONTALLY
WARNING *
Heat & Glo • SLF-550TR-IPI-E • 2118-901 Rev. B • 7/12
Note: Use SLP Series
components only.
Note: There MUST be a 25%
reduction in total H when using
fl ex vent except when using the
simple up and out installation
(see Figure 7.3).
H
1
V
1