Black level (master pedestal) adjustment

Black level (master pedestal)
adjustment
The black level can be adjusted when using a multiple
number of cameras including the unit. Ask your dealer to
perform this adjustment.
(Use an oscilloscope or waveform monitor for the
adjustment.)
Adjust the black level in accordance with the units and
devices used.
The black level can be adjusted only when Manual1,
Manual2 or Manual3 is selected as the shooting mode
(scene file).
When performing the operations
using the wireless remote control
1
Press the [M/IRIS] button.
Set the iris to the manual mode.
2
Press the [IRIS –] button.
The lens iris closes until the image is completely black.
3
Select Manual1, Manual2 or Manual3 by
following the procedure in "How to select the
shooting mode" (page 10) under "Selecting the
shooting modes (scene files)".
4
Press the [▲] or [▼] button to bring the cursor
to "Picture".
5
Press the [
] button.
The "Picture 1/3" sub-menu is displayed.
*** Picture 1/3 ***
Chroma Level
White Balance Mode
Color Temperature
R Gain
B Gain
Pedestal
Return
0
VAR
3200K
0
0
0
6
Press the [▲] or [▼] button, and bring the
cursor to "Pedestal".
*** Picture 1/3 ***
Chroma Level
White Balance Mode
Color Temperature
R Gain
B Gain
Pedestal
Return
7
Press the [
] button to start the "Pedestal"
value blinking.
8
Press the [▲] or [▼] button, change the
"Pedestal" value, and press the [
enter the selection.
9
Press the [MENU] button for 2 seconds.
The camera menu display is exited.
10
If necessary, press the [A/IRIS] button to adjust
the iris automatically.
When performing the operations using the controller
When using an AW-RP50, AW-RP120 or AK-HRP200:
Refer to the Operating Instructions of the controller.
0
VAR
3200K
0
0
0
] button to