Electronic Function; Abbreviation; Display Function - Fisher FSAI-SU-92AE2 Service Manual

Room air conditioner split wall-mounted type
Table of Contents

Advertisement

7. Electronic function

7.1 Abbreviation

T1: Indoor room temperature
T2: Coil temperature of evaporator
T3: Coil temperature of condenser
T4: Outdoor ambient temperature
T5: Compressor discharge temperature

7.2 Display function

7.2.1 Icon explanation on indoor display board.
Displays the temperature settings when the air
conditioner is operational.
Displays the room temperature in Fan and
Drying mode.
Displays the self-diagnostic codes.
Dispalys '
' for three seconds when Timer
ON, Fresh, Swing, Turbo or Silence feature is
activated.
Dispalys '
' for three seconds when Timer
OFF,Fresh, Swing, Turbo or Silence feature is
cancelled.
Dispalys '
Dispalys '
activated under heating mode.
Dispalys '
applicable).
Dispalys '
turned on (if applicable).
NOTE:
A guide on using the infrared remote is not
included in this literature package.
26
' under deforsting operation.
' when anti-cold air feature is
' during self clean operation (if
' when freeze protection is