4)
When the unit is running with follow me
function, if the PCB doesn't receive any signal
from remote controller for 7 minutes or pressing
FOLLOW ME button again, the follow me
function will be turned off automatically, and the
temperature will control the unit according to
the room temperature detected from its own
room
temperature
temperature.
7.4.15 Point check function
Press the LED button of the remote controller three times, and then press
the
AIR DIRECTION button three times in ten seconds, the buzzer will keep ring for two
seconds. The air conditioner will enter into the information enquiry status. You can press the LED
DISPLAY or
AIR DIRECTION button to check the next or front item's information within 27 seconds.
When the AC enter the "information enquiry" status, it will display the code name in 2 seconds, the
details are as follows.
Enquiry information
T1
T2
T3
T4
T2B
TP
TH
Targeted Frequency
Actual Frequency
Indoor fan speed
Outdoor fan speed
EXV opening angle
Compressor continuous running time
Causes of compressor stop.
Reserve
Reserve
Reserve
Reserve
Reserve
Reserve
Reserve
sensor
and
setting
Displaying code
T1
T2
T3
T4
Tb
TP
TH
FT
Fr
IF
OF
LA
CT
ST
A0
A1
0
1
2
3
4
7.4.13 Silence operation (optional)
Press the "silence" button on remote controller
to initiate SILENCE function. When the Silence
function is activated, the compressor running
frequency will keep lower than F2 and the
indoor unit will bring faint breeze, which will
reduce the noise to the lowest level and create
a quiet and comfortable room for you.
Meaning
T1 temp.
T2 temp.
T3 temp.
T4 temp.
T2B temp.
TP temp.
TH temp.
Targeted Frequency
Actual Frequency
Indoor fan speed
Outdoor fan speed
EXV opening angle
Compressor continuous
running time
Causes of compressor
stop.
32