Installation/Care/Use Manual
EDFP210FPC EDFP214FPC EDFP217FPC
Soft Sides
EDFP210FPC
Installer
To assure you install this model easily and correctly, PLEASE READ THESE SIMPLE
INSTRUCTIONS BEFORE STARTING THE INSTALLATION. CHECK YOUR INSTALLA-
TION FOR COMPLIANCE WITH PLUMBING, ELECTRICAL AND OTHER APPLICABLE
CODES. After installation, leave these instructions inside the fountain for future reference.
This Freeze Resistant Fountain is shipped in two separate cartons. The second carton(s)
contains the Freeze Resistant Package(s) LKFRB1 that are installed on an interior
heated wall. The interior space must maintain a minimum temperature of 50° F (10° C).
Refer to the Freeze Resistant Package for the rough-in dimensions for installation.
ALL SERVICE TO BE PERFORMED BY AN AUTHORIZED SERVICE PERSON
IMPORTANT! INSTALLER PLEASE NOTE.
THE GROUNDING OF ELECTRICAL EQUIPMENT SUCH AS TELEPHONE, COMPUTERS, ETC. TO
WATER LINES IS A COMMON PROCEDURE. THIS GROUNDING MAY BE IN THE BUILDING OR MAY
OCCUR AWAY FROM THE BUILDING. THIS GROUNDING CAN CAUSE ELECTRICAL FEEDBACK
INTO A FOUNTAIN, CREATING AN ELECTROLYSIS WHICH CAUSES A METALLIC TASTE OR AN
INCREASE IN THE METAL CONTENT OF THE WATER. THIS CONDITION IS AVOIDABLE BY USING
THE PROPER MATERIALS AS INDICATED. ANY DRAIN FITTINGS PROVIDED BY THE INSTALLER
SHOULD BE MADE OF PLASTIC TO ELECTRICALLY ISOLATE THE FOUNTAIN FROM THE BUILDING
PLUMBING SYSTEM.
EDFP210FP*B
EDFP214FP*B
Freeze Resistant Fountains
EDFP214FPC
IMPORTANT
EDFP217FP*B
EDFP217FPC
97565C (Rev. K - 1/08)

Advertisement

loading

Summary of Contents for Elkay Soft Sides EDFP210FP B Series

  • Page 1 EDFP210FP*B EDFP214FP*B EDFP217FP*B Installation/Care/Use Manual EDFP210FPC EDFP214FPC EDFP217FPC ™ Soft Sides Freeze Resistant Fountains EDFP210FPC EDFP214FPC EDFP217FPC Installer To assure you install this model easily and correctly, PLEASE READ THESE SIMPLE INSTRUCTIONS BEFORE STARTING THE INSTALLATION. CHECK YOUR INSTALLA- TION FOR COMPLIANCE WITH PLUMBING, ELECTRICAL AND OTHER APPLICABLE CODES.
  • Page 2 EDFP210FP*B EDFP214FP*B EDFP217FP*B 97565C (Rev. K - 1/08) PAGE 2...
  • Page 3 EDFP210FP*B EDFP214FP*B EDFP217FP*B 97565C (Rev. K - 1/08) PAGE 3...
  • Page 4 EDFP210FP*B EDFP214FP*B EDFP217FP*B 97565C (Rev. K - 1/08) PAGE 4...
  • Page 5 EDFP210FP*B EDFP214FP*B EDFP217FP*B 97565C (Rev. K - 1/08) PAGE 5...
  • Page 6 EDFP210FP*B EDFP214FP*B EDFP217FP*B CABLE SHEATH ADJUSTMENT To Increase Free Play To Reduce Free Play FIG. 5 FIG. 6 See Fig. 9 FIG. 7 See Fig. 5 FIG. 8 FIG. 9 97565C (Rev. K - 1/08) PAGE 6...
  • Page 7 EDFP210FP*B EDFP214FP*B EDFP217FP*B The freeze resistant package must be mounted on an interior wall in a heated area. The room temperature of the interior heated area must be 50° F (10° C) or higher. The freeze resistant package may be surface or recessed mounted. If recess mounted the surface of the cover must be flush with the interior wall surface.
  • Page 8: Parts List

    BIT - PINNED TORX 56280C EDGE TRIM FIG. 13 11, 19 FIG. 14 FOR PARTS, CONTACT YOUR LOCAL DISTRIBUTOR OR CALL 1.800.323.0620 ELKAY MANUFACTURING COMPANY • 2222 CAMDEN COURT • OAK BROOK, IL 60523 • 630.574.8484 97565C (Rev. K - 1/08) PAGE 8...

This manual is also suitable for:

Soft sides edfp214fp b seriesSoft sides edfp217fp b seriesSoft sides edfp210fpcSoft sides edfp214fpcSoft sides edfp217fpcSoft sides edfp214fpk ... Show all