Elkay Swirlflo EDFPB117FP Installation, Care & Use Manual

Elkay Swirlflo EDFPB117FP Installation, Care & Use Manual

Freeze resistant fountain

Advertisement

Quick Links

EDFPB117FP EDFPB117RFP EDFPBVM117FP EDFPBVM117RFP
Installation/Care/Use Manual
Installer
To assure you install this model easily and correctly, PLEASE READ THESE SIMPLE IN-
STRUCTIONS BEFORE STARTING THE INSTALLATION. CHECK YOUR INSTALLATION
FOR COMPLIANCE WITH PLUMBING, ELECTRICAL AND OTHER APPLICABLE CODES.
After installation, leave these instructions with the building owner for future reference.
This Freeze Resistant Fountain is shipped in three separate cartons. The second & third
carton contains the Freeze Resistant Package LKFRB1 that is installed on an interior heated
wall. Refer to the Freeze Resistant Package for the rough-in dimensions for installation.
ALL SERVICE TO BE PERFORMED BY AN AUTHORIZED SERVICE PERSON
IMPORTANT! INSTALLER PLEASE NOTE.
THE GROUNDING OF ELECTRICAL EQUIPMENT SUCH AS TELEPHONE, COMPUTERS, ETC. TO WATER
LINES IS A COMMON PROCEDURE. THIS GROUNDING MAY BE IN THE BUILDING OR MAY OCCUR AWAY
FROM THE BUILDING. THIS GROUNDING CAN CAUSE ELECTRICAL FEEDBACK INTO A FOUNTAIN, CREAT-
ING AN ELECTROLYSIS WHICH CAUSES A METALLIC TASTE OR AN INCREASE IN THE METAL CONTENT
OF THE WATER. THIS CONDITION IS AVOIDABLE BY USING THE PROPER MATERIALS AS INDICATED.
ANY DRAIN FITTINGS PROVIDED BY THE INSTALLER SHOULD BE MADE OF PLASTIC TO ELECTRICALLY
ISOLATE THE FOUNTAIN FROM THE BUILDING PLUMBING SYSTEM.
3/8" O.D. UNPLATED
1/4" O.D. TUBE
COPPER TUBE CONNECT
WATER INLET
COLD WATER SUPPLY
TO COOLER
NOTE: WATER FLOW
DIRECTION
FIG. 1
®
Swirlflo
Freeze Resistant Fountain
IMPORTANT
BUILDING WATER
INLET
SERVICE STOP
(NOT FURNISHED)
OPERATION OF QUICK CONNECT FITTINGS
SIMPLY PUSH IN
TUBE TO ATTACH
FIG. 2
1
TUBE IS
PUSH IN COLLET
SECURED
TO RELEASE TUBE
IN POSITION
PUSHING TUBE IN BEFORE
PULLING IT OUT HELPS TO
RELEASE TUBE
98010C (Rev. C - 6/08)

Advertisement

loading

Summary of Contents for Elkay Swirlflo EDFPB117FP

  • Page 1 EDFPB117FP EDFPB117RFP EDFPBVM117FP EDFPBVM117RFP Installation/Care/Use Manual ® Swirlflo Freeze Resistant Fountain Installer To assure you install this model easily and correctly, PLEASE READ THESE SIMPLE IN- STRUCTIONS BEFORE STARTING THE INSTALLATION. CHECK YOUR INSTALLATION FOR COMPLIANCE WITH PLUMBING, ELECTRICAL AND OTHER APPLICABLE CODES. After installation, leave these instructions with the building owner for future reference.
  • Page 2 EDFPB117FP EDFPB117RFP EDFPBVM117FP EDFPBVM117RFP EDFPB(V)M117FPC ROUGH-IN 12 1/8" 12 1/8" 307mm 307mm 7 1/4" 7 1/4" 184mm 184mm 12" 305mm MAX. WALL THICKNESS 9 3/4" 18 3/4" BACK 248mm 476mm PANEL 1 1/4" 1 1/4" 32mm 32mm SURFACE MOUNTING PLATE 43 5/8"...
  • Page 3 EDFPB117FP EDFPB117RFP EDFPBVM117FP EDFPBVM117RFP EDFPB117FPC ROUGH-IN 12 1/8" 12 1/8" 307mm 307mm 7 1/4" 7 1/4" 184mm 184mm 12" 32" 305mm 813mm MAX. WALL THICKNESS 16" 3 1/4" 406mm 82mm 1 1/4" 1 1/4" 32mm 32mm HANGER BRACKET MPW200 MTG. PLT. BACK PANEL 43 1/2"...
  • Page 4 EDFPB117FP EDFPB117RFP EDFPBVM117FP EDFPBVM117RFP EDFPB117RFPC ROUGH-IN 12 1/8" 12 1/8" 307mm 307mm 7 1/4" 7 1/4" 184mm 184mm 12" 305mm MAX. WALL THICKNESS 32" 813mm 16" 3 1/4" 406mm 82mm 1 1/4" 1 1/4" 32mm 32mm HANGER BRACKET BACK PANEL MPW200 MTG.
  • Page 5: Installation Instructions

    EDFPB117FP EDFPB117RFP EDFPBVM117FP EDFPBVM117RFP INSTALLATION INSTRUCTIONS 1. Wall should already be framed for the fountain using the positioning dimensions shown in Fig's. 3, 4, or 5. Shown dimensions pertain to installation location (framing must support up to 300 lbs. weight). These dimensions are required for compliance with ANSI Standard A117.1/ADA requirements.
  • Page 6 EDFPB117FP EDFPB117RFP EDFPBVM117FP EDFPBVM117RFP BASIN NOTE: When installing replacement bubbler and Bubbler Details pedestal, tighten nut (Item 5) only to hold parts snug in position. Do Not Over- tighten. BASIN VANDAL RESISTANT BUBBLER DETAIL FIG. 7 - Bubbler Details 98010C (Rev. C - 6/08)
  • Page 7: Parts List

    Back Panel Assy. LH ADA 27090C Hanger Bracket SEE FIG. 7 11,22 17,19 FIG. 9 FOR PARTS, CONTACT YOUR LOCAL DISTRIBUTOR OR CALL 1.800.323.0620 ELKAY MANUFACTURING COMPANY • 2222 CAMDEN COURT • OAK BROOK, IL 60523 • 630.574.8484 98010C (Rev. C - 6/08)

This manual is also suitable for:

Swirlflo edfpb117rfpSwirlflo edfpbvm117fpSwirlflo edfpbvm117rfpEdfpb117fpc