INSTALLATION, CARE & USE MANUAL
SWIRLFLO fountains with FLEXI-GUARD
EDFPB114C
INSTALLER
!
CAUTION:
Review these instructions before beginning installation. Be sure that installation
conforms to all plumbing, electrical and other applicable codes.
!
WARNING:
When installation is complete, ensure these instructions are left in the plastic bag
provided inside the installed unit for future reference.
!
WARNING:
Service to be performed by authorized service personnel only.
NOTE: It is common practice to ground electrical hardware such as telephones, computers and other devices
to available water lines. This can, however, cause electrical feedback in the plumbing circuit, which
results in an "electrolysis" effect occurring in the fountain. This may result in water which has a metallic
taste to it or has a noticeable increase in the metallic content of the water.
When inspecting plumbing circuit, remember the line may be grounded some distance from the
installation, and may occur outside the building or area in which the unit is being installed.
This condition can be avoided (in most cases) by using recommended materials during installation. Any
drain fittings provided by the installer should be made of plastic which will electronically isolate the
fountain from the remainder of the building's plumbing circuits.
EDFPB114C, EDFPBWM114C, EDFPBV114C, EDFPBWMV114C
T M
Page 1
EDFPBWM114C
97921C (REV. C - 3/05)
T M

Advertisement

loading

Summary of Contents for Elkay SWIRLFLO EDFPB114C

  • Page 1 EDFPB114C, EDFPBWM114C, EDFPBV114C, EDFPBWMV114C INSTALLATION, CARE & USE MANUAL SWIRLFLO fountains with FLEXI-GUARD EDFPB114C EDFPBWM114C INSTALLER CAUTION: Review these instructions before beginning installation. Be sure that installation conforms to all plumbing, electrical and other applicable codes. WARNING: When installation is complete, ensure these instructions are left in the plastic bag provided inside the installed unit for future reference.
  • Page 2 EDFPB114C, EDFPBWM114C, EDFPBV114C, EDFPBWMV114C Optional Figure 1 - Rough-in for EDFPB114C W/MP86 Mounting Plate Figure 2 - Rough-in Assembly For EDFPB114C LEGEND A = Water Inlet Location Left Or Right Side. 3/8” O.D. Unplated Copper Tube Connect. B = Fountain Waste Location Left Or Right Side. Waste Is Shown in Wall But May Be Behind Wall.
  • Page 3 EDFPB114C, EDFPBWM114C, EDFPBV114C, EDFPBWMV114C Optional Figure 3 - Rough-in for EDFPBWM114C Figure 4 - Rough-in Assembly for EDFPBWM114C LEGEND A = Water Inlet Location Left Or Right Side. 3/8” O.D. Unplated Copper Tube Connect. B = Fountain Waste Location Left Or Right Side. Waste Is Shown in Wall But May Be Behind Wall.
  • Page 4 EDFPB114C, EDFPBWM114C, EDFPBV114C, EDFPBWMV114C EDFPB114C Installation 5/16” Studs - Supplied with MP86 1. Wall should already be framed for the fountain using the positioning dimensions shown in Figure 1. Shown dimensions pertain to installation location (framing must support up to 300 lbs. weight). These dimensions are required for compliance with ANSI Standard A117.0.
  • Page 5 EDFPB114C, EDFPBWM114C, EDFPBV114C, EDFPBWMV114C EDFPBW114C Installation 1. Wall should already be framed for the fountain using the positioning dimensions shown in Figure 3. Shown dimensions pertain to installation location (framing must support up to 300 lbs. weight). These dimensions are required for compliance with ANSI Standard A117.0. 2.
  • Page 6 EDFPB114C, EDFPBWM114C, EDFPBV114C, EDFPBWMV114C 2, 3, 4 BASIN BUBBLER DETAIL NOTE: When installing replacement bubbler and pedestal, tighten nut (Item 7) only to hold parts snug in position. Do Not Overtighten. BASIN VANDAL RESISTANT BUBBLER DETAIL Figure 10 - Bubbler Details 97921C (REV.
  • Page 7 EDFPB114C, EDFPBWM114C, EDFPBV114C, EDFPBWMV114C See Fig. 10 See Fig. 10 Figure 11 - Fountain Body Figure 12 - Push Button 97921C (REV. C - 3/05) Page 7...
  • Page 8: Parts List

    EDFPB114C, EDFPBWM114C, EDFPBV114C, EDFPBWMV114C TROUBLESHOOTING & MAINTENANCE PARTS LIST Orifice Assembly: Mineral deposits on orifice ITEM NO. PART NO. DESCRIPTION can cause water flow to spurt or not regulate. Mineral 56073C Bubbler Assy deposits may be removed from the orifice by poking 40319C Fitting - Orifice with a small round file not over 1/8”...