IntelliFire™ Ignition System (Continued)
Pilot sparks, but will not
light.
Pilot lights but continues
to spark, and burner will
not ignite. (If the pilot
continues to spark after
the pilot flame has been lit,
flame rectification has not
occurred.)
14
Outdoor Lifestyles by Hearth & Home Technologies Inc. • Lanai 48/60 Owner's Manual • 4111-900 Rev. C • 06/21
Gas supply.
Ignitor gap is too large.
Module is not grounded.
Pilot valve solenoid
A short or loose connection in
flame sensing rod.
Poor flame rectification or
contaminated flame sensing
rod.
Module is not grounded.
Damaged pilot assembly or
contaminated flame sensing rod
Module
Verify that incoming gas line ball valve is "open". Verify
that inlet pressure reading is within acceptable limits.
Verify gap of igniter to right side of pilot hood. The gap
should be approximately .17 in. or 1/8 in. (3 mm).
Verify module is securely grounded to metal chassis of
appliance.
Verify that 1.5 to 1.8 VDC is supplied to pilot solenoid
from module. If below 1.5 volts, replace module. If 1.5
volts or greater, replace valve.
Verify all connections to wiring diagram in manual. Verify
connections underneath pilot assembly are tight. Verify
connections are not grounding out to metal chassis, pilot
burner, pilot enclosure or screen if present, or any other
metal object.
Verify correct pilot orifice is installed and gas inlet is set
to pressure specifications. Check pilot for soot. Clean if
necessary.
Verify module is securely grounded to metal chassis of
appliance. Verify that wire harness is firmly connected to
the module.
Verify that ceramic insulator around the flame sensing
rod is not cracked, damaged, or loose. Verify connection
from flame sensing rod to white sensor wire. Polish
flame sensing rod with fine steel wool to remove any
contaminants that may have accumulated on flame
sensing rod. Verify continuity with a multimeter with
ohms set at lowest range. Replace pilot if any damage is
detected.
Turn wall control to OFF position. Remove ignitor wire "I"
from module. Turn wall control to ON position. If there is
no spark at "I" terminal module must be replaced. If there
is a spark at "I" terminal, module is fine.