Mounting

4.2 Installing on an S7-300 standard rail

4.2
Installing on an S7-300 standard rail
Procedure
Danger of injury by falling objects
When used in an area with heavy load, the device is not adequately supported on an S7-
300 standard rail. Under such conditions, the device can come out of the mounting.
If you use the device in a heavy load area, mount it on an S7-1500 mounting rail or on the
wall.
Follow the steps below to fit the SCALANCE W774/W734 to an S7-300 standard rail:
1. Place the device on the upper edge of the S7-300 standard rail as shown in the figure.
2. Screw the housing to the S7-300 standard rail. The required screw ships with the
SCALANCE W774/W734.
16
WARNING
SCALANCE W774-1/W734-1
Operating Instructions, 09/2015, C79000-G8976-C325-06