LED Indicators
Power Requirements
Power Consumption
Connector
DI and DO
Alarm
Reset Button
Management
Management Interfaces
IP Version
Operation Mode
System: Power 1, Power 2, Fault, SYS, I/O(ICS-2400T only)
TP/SFP Port: Link/Active
Serial Port: Tx and Rx
9~48V DC / 24V AC, redundant power with reverse
polarity protection
Full Loading
Full Loading
9VDC: 0.35A
9VDC: 0.44A
(3.15 watts)
(3.96 watts)
12VDC: 0.28A
12VDC: 0.33A
(3.36 watts)
(4 watts)
24VDC: 0.12A
24VDC: 0.17A
(3 watts)
(4.08 watts)
48VDC: 0.08A
48VDC: 0.1A
(3.84 watts)
(4.8 watts)
Removable 6-pin terminal block for power input
Pin 1/2 for Power 1, Pin 3/4 for fault alarm, Pin 5/6 for Power 2
Provides one relay output for power failure
Alarm relay current carry ability: 1A @ DC 24V
< 5 sec: System reboot
> 5 sec: Factory default
Web management
Telnet Console management
Windows-based VCOM Utility management
PLANET Smart Discovery Utility
IPv4 and IPv6
TCP Server
TCP Client
UDP Client
Virtual COM
RFC2217
User's Manual of ICS-2x00T Serial Device Server Series
Full Loading
9VDC: 0.44A
(3.96 watts)
12VDC: 0.33A
(4 watts)
24VDC: 0.17A
(4.08 watts)
48VDC: 0.1A
(4.8 watts)
N/A
14
12~48V DC, redundant power with
reverse polarity protection
Full Loading
Full Loading
12VDC: 0.326A
12VDC: 0.419A
(3.8 watts)
(5.1 watts)
24VDC: 0.176A
24VDC: 0.227A
(4.2 watts)
(5.4 watts)
48VDC: 0.114A
48VDC: 0.136A
(5.4 watts)
(6.5 watts)
2 digital inputs:
Level 0:
-24V~2.1V
(±0.1V)
Level 1: 2.1V~24V
(±0.1V)
Input Load to 24V
DC, 10mA max.
2 digital outputs:
Open collector to
24V DC, 100mA
max.