Electrical Precautions:
1.
All connections and conduits from the Generator to the load must only be installed
by trained and licensed electricians, and in compliance with all relevant local, state,
and federal electrical codes and standards, and other regulations where applicable.
2.
The Generator must be properly earth-grounded by a licensed electrician in
accordance with all relevant electrical codes and standards before operation.
3.
If an extension cord (not included) is used, make sure to use only UL
cords having the correct gauge and length. (See Figure A.)
REQUIRED MINIMUM EXTENSION CORD GAUGE – 120/ 240 VOLT
NAMEPLATE
AMPERES
(At Full Load)
0 - 5
5.1 - 8
8.1 - 12
12.1 - 15
15.1 - 20
SKU 90236
For technical questions, please call 1-800-444-3353.
FIGURE A
EXTENSION CORD LENGTH
0 - 25
25 - 50
Feet
Feet
16
16
16
16
14
14
12
12
10
10
50 -100
100 – 150
Feet
Feet
16
12
14
10
12
-
10
-
10
-
®
approved
150– 200
Feet
12
-
-
-
-
Page 10