Complete Installation - Jenn-Air JGC2530EB00 Installation Instructions Manual

30" 76.2 cm and 36" 91.4 cm gas built-in cooktop
Hide thumbs Also See for JGC2530EB00:
Table of Contents

Advertisement

Complete Connection
1. Open the manual shutoff valve in the gas supply line. The
valve is open when the handle is parallel to the gas pipe.
A
A. Closed valve
B. Open valve
2. Test all connections by brushing on an approved
noncorrosive leak-detection solution. If bubbles appear, a
leak is indicated. Correct any leak found.
3. Install all burner caps and burner bases.
A
B
C
Standard Burner
A. Cap
B. Spreader
C. Electrode
Burner installation:
To install the burner base, insert the igniter electrode into the
burner base hole.
Install surface grates:
Each burner has a locating ridge on the cooktop surface that
mates with the bottom of the surface grate. To install the burner
grate; align the recess in the burner grate with the locating ridge
on the cooktop. Evenly and gently lower the burner grate onto
the cooktop surface. Ensure the four rubber feet of the surface
grate are contacting the cooktop surface. If all four feet are not
touching, remove the surface grate and ensure that the mating
surfaces are debris-free. Reinstall burner grate.
NOTE: On 36" (91.4 cm) models; the center surface grate is
different than the left and right grates.
8
B
A
B
C
Dual Flame Burner
A. Cap
B. Spreader
C. Electrode
WARNING
Electrical Shock Hazard
Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
Do not use an extension cord.
Failure to follow these instructions can result in death,
fire, or electrical shock.
4. Plug into a grounded 3 prong outlet.

Complete Installation

Electronic Ignition System
Check Operation of Surface Burners
1. Push in and turn the surface burner control knobs to the
HI position.
The surface burner flame should light within 4 seconds. The
first time a surface burner is lit, it may take longer than 4
seconds to light because of air in the gas line.
2. Check the flame on HI for a blue color. It should be clean
and soft in character. No yellow tip, blowing or lifting of flame
should occur. Occasional orange flashes are normal and
reflect different elements in the air or gas.
3. Repeat for the LO position.
4. Repeat for the SIM position.
5. After verifying the proper burner operation, turn the control
knobs to OFF.
If burners do not light properly:
Turn the surface burner control knob to the OFF position.
Check that the power supply cord is plugged in and the
circuit breaker has not tripped or the fuse blown.
Check that the gas shutoff valve is set to the "open" position.
Check that the burner bases and caps are properly
positioned on the burners.
A. Correct
B. Incorrect
Recheck the operation of the surface burners. If a burner does
not light at this point, call 1-800-JENN-AIR (536-6247).
A
B
B

Advertisement

Table of Contents
loading

This manual is also suitable for:

Jgc2536eb00

Table of Contents