Complete Installation - Jenn-Air JGC3215GS Installation Instructions Manual

Hide thumbs Also See for JGC3215GS:
Table of Contents

Advertisement

Available languages

Available languages

Complete Connection
1. Open the manual shut-off valve in the gas supply line. The
valve is open when the handle is parallel to the gas pipe.
A
A. Closed valve
B. Open valve
2. Test all connections by brushing on an approved
noncorrosive leak-detection solution. If bubbles
appear, a leak is indicated. Correct any leak found.
NOTE: When a single shut-off valve is used for a multi-unit
installation, closing the valve will shut off the gas supply to
all connected units.
3. Install all burner caps and burner bases.
Single Burner
A. Cap
B. Spreader
C. Electrode
A
B
C
D
Dual Flame Burner
A. Inner cap
B. Outer cap
C. Spreader
D. Electrode
Single and Double Burner installation:
To install the spreader (B), insert the electrode (C) into the
spreader hole. Install the cap (A) on the spreader (B).
Dual Flame Burner:
Install the inner and outer caps (A and B) on the dual
flame burner.
Install surface grate:
The surface grate is positioned correctly when it sits level
on the cooktop and does not rock or wobble.
B
A
B
C
Double Burner
A. Cap
B. Spreader
C. Electrode
4. Plug into a grounded 3 prong outlet.

Complete Installation

Electronic Ignition System
Check Operation of Surface Burners
1. Push in and turn the surface burner control knobs to IGNITE.
The surface burner flame should light within 4 seconds.
The first time a surface burner is lit, it may take longer than
4 seconds to light because of air in the gas line.
2. Turn the control knob to HI and check for a blue-colored
flame. It should be clean and soft in character. No yellow tip,
blowing, or lifting of flame should occur. Occasional orange
flashes are normal and reflect different elements in the air
or gas.
3. Repeat for Lo.
NOTE: For the double burner, only the inner ring will have
a flame.
4. Repeat for Simmer.
5. After verifying the proper burner operation, turn the control
knobs to OFF.
If burners do not light properly:
Turn the surface burner control knob to OFF.
Check that the power supply cord is plugged in and the
circuit breaker has not tripped or the fuse blown.
Check that the gas shut-off valve is set to the open position.
Check that the burner bases and caps are properly
positioned on the burners.
A. Correct
B. Incorrect
Recheck the operation of the surface burners. If a burner does
not light at this point, call 1-800-JENN-AIR (1-800-536-6247).
9

Advertisement

Table of Contents
loading

Table of Contents