Furuno FR-1918V-BB Installation Manual page 22

River radar
Hide thumbs Also See for FR-1918V-BB:
Table of Contents

Advertisement

2. WIRING
How to fabricate cables connected to the FRP_TB board
(03P9548)
Signal cable RW-0013
(Fold back outer shield over the vinyl sheath.)
Vinyl sheath
Vinyl tape
Set this part in the cable clamp.
TTYCSLA cables
Armor
Secure tape with
cable tie (supplied).
Cable lengths of L1, L2 and L3 (mm)
Connector No.
J612 (NMEA1)
J613 (NMEA2)
J614 (NMEA3)
J615 (NMEA4)
J616 (NMEA5)
J617 (NMEA6)
J619 (ROT/RUDDER)
2-8
100
240
Wind the inner shield around the outer shield.
Coaxial cable
L2
Drain wire
Sheath
Vinyl tape
Set this part in cable clamp.
Pass the vinyl tape (local suppy) onto the drain wire. Attach a
crimp-on lug (preattached to the processor unit) to the drain wire.
Fasten the crimp-on lug to its original location.
Cable type
TTYCSLA-1T
TTYCSLA-4
TTYCSLA-1
TTYCSLA-1
TTYCSLA-4
TTYCSLA-4
TTYCSLA-7
Pull out wires from the inner shield.
Inner shield
8
Connect to WAGO connector.
15 515
Fold back shield.
L3
L1
L1 to 3: See the table shown on next page.
Crimp-on lug
L1
L2
120
60
200
60
120
60
60
100
250
80
230
80
200
60
Conductor
8
5
L3
80
150
100
120
200
200
120

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fr-1908v-bb

Table of Contents