Furuno FR-1918V-BB Installation Manual page 18

River radar
Hide thumbs Also See for FR-1918V-BB:
Table of Contents

Advertisement

2. WIRING
10. Connect the signal cable to the terminal board TB801, TB802 and TB803 on the
03P9488 board, referring to the interconnection diagram.
TB801
(WAGO connector)
Cable clamp
How to connect wires to WAGO connector
Wire
Twist
11. Pass the coaxial cable under the transceiver fixing plate (arrow) and the clamp
(dashed circle).
2-4
Press downward.
Procedure
Terminal
1. Twist the core.
opener
2. Set terminal opener and press it downward.
3. Insert the core into hole.
4. Remove the terminal opener.
WAGO
connector
5. Pull the wire to confirm that it is secure.
Terminal opener
03P9488 board
TB803
(High-Voltage line)
How to insert the core
1. Push white lever.
2. Insert a core.
Core
Core
entrance
entrance
3. Release white lever.
TB802
(WAGO connector)
Cable clamp
Motor

Advertisement