5

Maintenance and service

5.1
Overview: Maintenance and
service
The installer has to perform a yearly maintenance. You can find the
contact/helpdesk number via the user interface.
As end user, you have to:
▪ Keep the area around the unit clean.
▪ Keep the user interface clean with a soft damp cloth. Do NOT use
any detergents.
▪ Regularly check if the water pressure is above 1 bar.
Refrigerant
This product contains fluorinated greenhouse gases. Do NOT vent
gases into the atmosphere.
Refrigerant type: R410A
Global warming potential (GWP) value: 2087.5
NOTICE
In Europe, the greenhouse gas emissions of the total
refrigerant charge in the system (expressed as tonnes CO
equivalent) is used to determine the maintenance intervals.
Follow the applicable legislation.
Formula to calculate the greenhouse gas emissions:
GWP value of the refrigerant × Total refrigerant charge [in
kg] / 1000
Please contact your installer for more information.
WARNING
The refrigerant in the system is safe and normally does not
leak. If the refrigerant leaks in the room, contact with a fire
of a burner, a heater or a cooker may result in a harmful
gas.
Turn off any combustible heating devices, ventilate the
room and contact the dealer where you purchased the unit.
Do not use the system until a service person confirms that
the portion where the refrigerant leaks is repaired.
5.2
To find the contact/helpdesk
number
Prerequisite: You switched the permission level to Advanced end
user.
1 Go to [6.3.2]:
> Information > Error handling > Contact/
helpdesk number.
EBLQ+EDLQ011~016CA(3)V3+W1
Daikin Altherma low temperature monobloc
4P537989-1 – 2018.05
6

Troubleshooting

6.1
Symptom: You are feeling too cold
(hot) in your living room
Possible cause
The desired room temperature is
too low (high).
The desired room temperature
cannot be reached.
6.2
Symptom: The water at the tap is
too cold
2
Possible cause
You ran out of domestic hot
water because of unusual high
consumption.
The desired DHW tank
temperature is too low.
6.3

Symptom: Heat pump failure

When the heat pump fails to operate, the backup heater and booster
heater can serve as an emergency heater and either automatically
or non-automatically take over the heat load.
▪ When auto emergency is activated and a heat pump failure
occurs:
▪ The backup heater will automatically take over the heat load.
▪ The booster heater will automatically take over the domestic hot
water production.
▪ When auto emergency is not activated and a heat pump failure
occurs, the domestic hot water and space heating operations will
stop and need to be recovered manually. The user interface will
then ask you to confirm whether the backup heater or booster
heater can take over the heat load or not.
When the heat pump fails,
5 Maintenance and service
Corrective action
Increase (decrease) the desired
room temperature.
If the problem recurs daily, do
one of the following:
▪ Increase (decrease) the room
temperature preset value.
▪ Adjust the room temperature
schedule.
Increase the desired leaving
water temperature in accordance
with the heat emitter type.
Corrective action
If you immediately need domestic
hot water, activate the DHW tank
booster mode. However, this
consumes extra energy.
If you can wait, overrule
(increase) the active or next
scheduled desired temperature
so that more hot water will be
produced exceptionally.
If the problems recurs daily, do
one of the following:
▪ Increase
the
DHW 
temperature preset value.
▪ Adjust
the
DHW 
temperature
Example:
Program
additionally
heat
DHW  tank to a preset value
(Storage eco = lower tank
temperature) during the day.
will appear on the user interface.
Operation manual
tank
tank
schedule.
to
up
the