4-Wire Resistance Measurement - Fluke FL8808A User Manual

Table of Contents

Advertisement

8808A
Users Manual

4-Wire Resistance Measurement

The Meter incorporates two methods of making a four-wire resistance measurement. The
traditional method is to use four meter leads to connect the Meter to the resistance to be
measured. The optional 2X4 Wire test leads simplifies the four-wire measurement so you
only have to plug in two test leads to the Input HI and LO connectors of the meter.
To perform a 4-wire resistance measurement using four test leads:
To make a four-wire resistance measurement using Fluke's 2X4 test leads:
1. Connect the test leads to the Meter's input connectors as show in Figure 3-7.
2. Press N. 2*4 Wire is displayed.
3-12
1. Connect test leads between the Meter and the circuit under test as shown in
Figure 3-6.
2. If required, press O to select 4-wire resistance measurement mode. 4 Wire is
displayed.
The function and measurement are displayed.
Figure 3-6. 4-Wire Resistance Measurement
INPUT
SENSE
V
4 W
2 2
2W/4W
HI
HI
1000 V
CAT I
1000V
300V
MAX
750V
600 V
CAT II
1V
LO
LO
500 V pk
200 mA
MAX
10 A
MAX
mA
10A
eue12.eps

Advertisement

Table of Contents
loading

This manual is also suitable for:

8808a

Table of Contents