Error Log Codes - Frymaster FootPrint OCF30G Service & Parts Manual

Hide thumbs Also See for FootPrint OCF30G:
Table of Contents

Advertisement

1.14.4

Error Log Codes

Code
ERROR MESSAGE
E03
ERROR TEMP PROBE FAILURE
E04
HI 2 BAD
E05
HOT HI 1
E06
HEATING FAILURE
E08
ERROR ATO BOARD
E17
ERROR ATO PROBE
E20
INVALID CODE LOCATION
E21
FILTER PAPER PROCEDURE ERROR
(Change Filter Paper)
E22
OIL IN PAN ERROR
E25
RECOVERY FAULT
E27
LOW TEMP ALARM
EXPLANATION
TEMP Probe reading out of range
High limit reading is out of range.
High limit temperature is past 410°F (210°C), or
in CE countries, 395°F (202°C)
A component has failed in the high limit circuit
such as controller, interface board, contactor or
open-high limit.
ATO board connection lost; ATO board failure
ATO RTD reading out of range
SD card removed during update
25-hour or customer-set timer has expired.
Oil may be present in the filter pan.
Recovery time exceeded maximum time limit.
Recovery time should not exceed 1:40 for
electric.
Oil temperature has dropped 40°F (17°C) below
setpoint temperature in idle mode or 45°F (25°C)
in cook mode. (This message may appear if a
product is dropped and the start cook button is
not pressed immediately or if too large of cook
loads are dropped.)
1-36

Advertisement

Table of Contents
loading

This manual is also suitable for:

Footprint ocf30 series

Table of Contents