Frymaster FootPrint OCF30G Service & Parts Manual page 21

Hide thumbs Also See for FootPrint OCF30G:
Table of Contents

Advertisement

Spacer
4
See page 1-17 for reassembly illustration.
11. Remove the upper burner rails (11). NOTE: For the following steps, refer to the frypot exploded view on page 1-
16 for component identification.
12. Remove any residual insulation, sealant, and/or oil from the exterior of the frypot.
13. Place the "L" shaped pieces of the combustion chamber insulation (1) in the front and rear corners of both upper
rail-retaining slots. (See page 1-17).
14. Using a mallet and short piece of wood, tap the corner tabs of the combustion chamber over the insulation to
ensure a solid seal of the burner.
15. Install the upper burner rails (2) with the heat deflectors slanting toward the rear of the frypot. The rails will
cover the "L" shaped pieces of combustion chamber insulation previously installed.
16. Place the upper inner combustion chamber insulation and insulation retainers (3) on the top two studs on each side
of the front of the frypot and secure with ¼"-20 washer-nuts. It is normal for the retainers to slice off the
overhanging insulation.
17. Place the lower rear combustion chamber insulation (4) on the lower four studs at the rear of the frypot.
18. Place one 1.625-inch tubular spacer (5) on each of the flue assembly (upper) studs at the rear of the frypot.
NOTE: There are three different sizes of spacers. Verify the size to ensure the correct spacers are installed.
19. Press the flue assembly (6) over the burner rails. It may be necessary to use a rubber mallet or screwdriver to
align the components. Use four ¼"-20 washer nuts to secure the flue assembly. Do not tighten the retainer
nuts at this point. They should be finger-tight only. NOTE: The flue edge will cover one to two inches of the
lower insulation.
20. Install the lower rear combustion chamber back(s) and retainer(s) (7) with the flanged edge(s) against the flue.
Secure with ¼"-20 washer nuts. NOTE: Full-vat units have two-piece backs and four retainers. Dual-vat units
come with one-piece backs and only two retainers.
2
s
6
Disassembling A Frypot
5
(Full Vat Illustrated)
3
11
8
7
1-15
10
Spacer
9
1