3.5

Alarms

The SC-120 can alert you with audio and visual alarms when GPS data and
DGPS data are lost. To set the alarm mode;
1. Press the [MENU] key to show the menu.
2. Choose ALARMS and press the [ENT] key.
3. Press the [ENT] key.
4. Use ▲ or ▼ on the Omnipad to choose buzzer type desired.
SHORT:
LONG:
CONSTANT: Continuous beep
5. Press the [ENT] key.
6. Select DGPS, HDG RESTORATION or HDG BACKUP as appropriate.
DGPS:
HDG RESTORATION: Choose how to restore GPS signal, automatically
HDG BACKUP:
MAIN MENU
ALARMS
MESSAGES
GPS SETUP
SYS SETUP
SOFT VER.
OTHERS
Main menu
ALARMS
BUZZER
:
DGPS
: OFF
HDG RESTORATION: MAN
HDG BACKUP: 5MIN
Alarm menu
Alarm menu, GPS buzzer options
Two short beeps
Three long beeps
Turns on/off DGPS alarm.
or manually.
Choose how long to wait before stopping output of
heading, when GPS signal is lost.
SATELLITE
DGPS
I/O SETUP
INST MENU
ERASE
TRIP MENU
LONG
3. OPERATION
3-5