2. BASIC OPERATION
2.4.2
Selecting the data shown on Normal Display 2, Data Display
and Graphic Display
Display modes may be set up to suit your operating needs as below.
Selecting data
In the STBY mode, you can select which data you want to display in the columns
shown in the figure below. For Normal Display 1 and 2, you may choose which
data you want to show on the analog indicator.
1. Press the [STBY] key to show the STBY mode.
2. Press the [STBY] key several times to show the one of screens shown above,
which you want to change the data.
3. Press the course control knob.
The first column is circumscribed with a rectangle.
4. Press the [PORT] or [STBD] key to select the column desired.
Note that there is one column in the Normal Display 1 and Graphic data.
5. Rotate the course control knob to select the data you want to show.
Available data and analog indicators are listed on the next page.
6. Press the course control knob to finish.
2-4
STBY
20.5
HDG
145.9
Normal Display 1
STBY
HDG
116.5
20.4
Data Display*
STBY
HDG
145.9
Normal Display 2
STBY
HDG
20.4
Graphic Display
*: Two or three data can be selected on installing.
Analog indicator column
Data column
20.5
116.5