3. Attach vent pipe assembly to the fire-
place. Set fireplace in front of it's per-
manent location to insure minimum
clearances. Mark the wall for a 10"
square hole (for noncombustible mate-
rial such as masonry block or concrete,
1
a 7
/2" diameter hole is acceptable).
See Figure 13. The center of the hole
should line up with the center-line of
the horizontal rigid vent pipe. Cut a
10"x10" (254mm x 254mm) square
hole through combustible exterior wall
1
(7
/2" [190mm] diameter hole if non-
combustible). Frame as necessary (see
Figure 13).
4" Clamp
Female
7" Clamp
Locking
Lugs
Spacer
Spring
4" Flex
Male
Pipe
Slots
7" Flex
Pipe
Rigid Vent Pipe Flexible Vent Pipe
Figure 12 - Vent Pipe Connections
Vent Opening
Combustible Wall
10"
(254mm)
10"
(254mm)
(Framing
Detail)
Vent Opening
Noncombustible Wall
1
7
/
"
2
(190mm)
Figure 13 - Vent Opening Requirements
104493
4. Apply a bead of non-hardening mastic
around the outside edge of the vent cap.
Position the vent cap in the center of
the 7
1
/
" or 10" hole on the exterior
2
wall with the arrow on the vent cap
pointing up. Insure proper clearance of
1" to combustibles is maintained. At-
tach the vent cap with four wood screws
supplied (see Figure 14). Note : Re-
place the wood screws with appropri-
ate fasteners for stucco, brick, concrete,
or other types of siding.
WARNING: Do not recess vent
termination in to any wall. This
will cause a fire hazard.
For vinyl siding use vinyl siding stand-
offs between vent cap and exterior wall.
The vinyl siding standoff prevents ex-
cessive heat from melting the vinyl sid-
ing material. Bolt the vent cap to the
standoff. Apply non-hardening mastic
around outside edge of the standoff in-
stead of the vent cap assembly. Use
wood screws provided to attach the
standoff. See Figure 15.
5.
Slide the wall thimble over the vent pipe
before connecting the horizontal run to
the vent cap (see Figure 16).
Apply Mastic
to All Four
Sides
Vent Cap
Figure 14 - Installing Horizontal Vent Cap
9
OWNER'S MANUAL
6.
Carefully move the fireplace with vent
assembly attached toward the wall and
insert the vent pipe into the horizontal
termination. The pipe overlap should
be a minimum of 1
to the outer pipe connection. Fasten all
vent connections with screws provided.
Refer to Fireplace Installation on page
16 for instructions on securing unit to
framing or floor.
7.
Slide the wall thimble against the inte-
rior wall surface and attach with screws
provided (see Figure 16).
Nut
Apply Mastic
to All Four Sides
Figure 15 - Installing Vinyl Siding Standoff
Wood
Screw
Vent Cap
(Horizontal
Termination)
Figure 16 - Connecting Vent Cap with
Horizontal Vent Pipe
1
/
". Apply silicone
4
Cut Vinyl Siding
Away to Fit
Standoff
Wood Screw
Standoff
Bolt
Vent Cap
Interior Wall
Surface
Wall
Thimble
Screw
Horizontal
Vent Pipe
Continued