 Compare indoor and outdoor temperature. The temperatures should be within 4
degrees to be within tolerance. The humidity should be within 14% to be within
tolerance.
 If the sensor reads correctly when next to the Professional weather station then
try a different location outside.
 Look for heat sources such as sunlight, door or window frames, or reflected
heat.
 Check batteries. Overpowered or underpowered batteries can cause this
reading.
 Replace sensor.
 RF (radio frequency) communication may come and go occasionally. This can be
normal in some environments (e.g. moister climates).
 If a sensor goes out, please wait 2-4 hours for it to reconnect on its own. Please
be patience – these stations can reconnect on, after many hours out.
 RF (radio frequency) communication is not always 100% on.
 Certain temporary conditions can cause it to go out for a time (e.g. 100%
humidity).
If a miss happens:
 Hold the DOWN ARROW button for 5 seconds to search for sensor.
 The units try for 20 minutes to reconnect. After 20 minutes, the sensor stops
trying for an hour (to preserve battery life). After the 1-hour break, the sensor
will start another 20-minute re-connect cycle.
Distance/Resistance
wall, window, tree etc., between the display and the sensor. UV coated windows
may actually reflect the signal. Stucco walls will absorb the signal.
 Check batteries. This is our primary warranty issue.
 Test a new set of Alkaline batteries. Write down the date of installation and the
voltage of the batteries.
 When the batteries fail, please note the date and voltage again. This is helpful in
determining the problem.
 Check the distance and resistance between the sensor and Professional weather
station. Sensors at the end of the range may work while batteries are fresh but
not after they drain a bit.
 Check for leaking batteries, which may damage the sensor.

HUMIDITY SHOWS OFL BUT TEMPERATURE WORKS

La Crosse Technology, Ltd.

OUTDOOR READINGS ARE STUCK OR OFL

INTERMITTENT SENSOR READINGS

can cause loss of sensor signal. Avoid having more than 1

SENSOR DRAINS BATTERIES QUICKLY