 The thermo-hygro sensor reads the environment. When the sensor reads high during the day
but not at night it is a mounting problem.
 Side-by-side test: Bring the wind/thermo-hygro sensor in the house and place it next to the
station for 2 hours.
 Compare indoor and outdoor temperature. The temperatures should be within 4 degrees to be
within tolerance. The humidity should be within 14% to be within tolerance.
 If the sensor reads correctly when next to the wind speed station then try a different location
outside.
 Look for heat sources such as sunlight or reflected heat.
 Check batteries. Overpowered or underpowered batteries can cause this reading.
 Replace sensor.
 RF (radio frequency) communication may come and go occasionally. This can be normal in
some environments (e.g. moister climates).
 If a sensor goes out, please wait 2-4 hours for it to reconnect on its own. Please be patience –
these stations can reconnect on, after many hours out.
 RF (radio frequency) communication is not always 100% on.
 Certain temporary conditions can cause it to go out for a time (e.g. 100% humidity).
If a miss happens:
 Hold the WIND button for 5 seconds to search for sensor.
 The units try for 20 minutes to reconnect. After 20 minutes, the sensor stops trying for an hour
(to preserve battery life). After the 1-hour break, the sensor will start another 20-minute re-
connect cycle.
Distance/Resistance
window, tree etc., between the display and the sensor. UV coated windows may actually
reflect the signal. Stucco walls will absorb the signal.
 Check batteries. This is our primary warranty issue.
 Test a new set of alkaline batteries. Write down the date of installation and the voltage of the
batteries.
 When the batteries fail, please note the date and voltage again. This is helpful in determining
the problem.
 Check the distance and resistance between the sensor and station. Sensors at the end of the
range may work while batteries are fresh but not after they drain a bit.
 Check for leaking batteries, which may damage the sensor.
 Enter the program menu to select in Fahrenheit (ºF) or Celsius (ºC).
La Crosse Technology, Ltd.

OUTDOOR READINGS ARE STUCK OR OFL

INTERMITTENT SENSOR READINGS

can cause loss of sensor signal. Avoid having more than one wall,

SENSOR DRAINS BATTERIES QUICKLY

FAHRENHEIT/CELSIUS