Installation Procedure
Step 2 Checking and preparing
accessories and tools
3-wire
Power Cable (option)
Drain Plug
Rubber Leg
Flare Nuts, 15.88mm
outer pipe diameter
Tube connector
(Pipe 12.70mm;
Bolt 9.52mm)
NOTE
• Attach Energy Label to the outdoor unit properly
when installing.
• Wire assembly cables are optional. If they are not
supplied, use standard cables.
• The drain plug and the rubber legs are included
only when the air conditioner is supplied without
assembly pipes.
• If these accessories are supplied, they are in the
accessory package or outdoor unit package.
English
10
2-wire
Assembly Cable (option)
Energy Label
Installation Manual
Flare Nuts, 9.52mm
outer pipe diameter
Tube connector
(Pipe 12.70mm;
Bolt 15.88mm)

Step 3 Fixing the outdoor unit in place

Install the outdoor unit on a rigid and stable base to
prevent disturbance from any noise caused by vibration.
When installing the unit at a height or in a location
exposed to strong winds, fix the unit securely to a
support (i.e., a wall or a ground).
1 Position the outdoor unit so that the air flow is
directed towards the outside, as indicated by the
arrows on the top of the unit.
2 Attach the outdoor unit to the appropriate support
using anchor bolts.
• The earthing wire for the telephone line cannot be
used to earth the air conditioner.
3 If the outdoor unit is exposed to strong winds, install
shield plates around the outdoor unit, so that the fan
can operate correctly.
NOTE
• Certainly fix up its rubber leg in order to prevent its
vibration and noise.
620 mm
620 mm
Rubber leg
CAUTION
• Install a drain outlet at the lowest end around the
base for outdoor unit drainage.
• When installing the outdoor unit on the roof,
waterproof the unit and check the ceiling strength.