TESTING CHLORINE LEVELS IN WATER - DIALING IN

1. Put the Whole House Water Filter into bypass. (See page12 for bypass position)
2. Turn on the nearest cold water faucet to the system.
3. Listen and watch the pump to make sure it is pumping. The pump should pulse and not run continuously. If the water is off, the pump
will stop.
4. Let the water run for 15 minutes.
5. After 15 minutes, use a chlorine test strip to test a sample of water from the cold water faucet.
a. The optimum chlorine level reading is 2.6ppm on the test strip.
b. If you do not have a reading of chlorine you will need to add 3 more cups of bleach to the solution tank and mix. Note the new total
of bleach to 17 gallons water. Repeat steps 4 & 5 to achieve a new sample for testing. Double check to make sure the Water Filter is
in bypass. Page 12 shows the bypass position.
c. If your reading is close to 2.6ppm then you will unlock the dosage adjustment on the injector pump and rotate up two full turns.
Re-lock the dosage adjustment and repeat steps 4 & 5 to achieve a new sample for testing.
6. If you needed to test another sample and you still do not have a reading of chlorine add another 3 cups of bleach and mix. Note the
new total of bleach to 17 gallons of water. Repeat steps 4 & 5 to achieve a new sample for testing.
7. If your reading is close to 2.6ppm then you will unlock the dosage adjustment on the injector pump and rotate up two full turns.
Re-lock the dosage adjustment and repeat steps 4 & 5 to achieve a new sample for testing.
IMPORTANT
If after testing again there is still no reading of chlorine we recommend calling in to speak with a
Technical Support representative. 877-842-1635
ELECTRONIC HEAD CONTROL INFORMATION
Power on LED
A green LED is ON when power is applied to the control and the microprocessor is operating properly.
Service Required
If the message "For Service Call" or "Service Required" displays in the window of the control without showing the time of day, the control
valve has encountered a problem, such as failure to reach the proper position during regeneration. The valve, the motor assembly, and
board must be checked to diagnose and fix this problem.
Note
It is normal for the message 'For Service Call' followed by a phone number to scroll across the second line of the display.
The time of day & capacity remaining will appear on line 1 during normal operation.
Time Clock
The time clock maintains the time of day for an extended period of time in the event of power loss. A super capacitor provides this
function and eliminates the need of a battery. In the event the power is off past the charge of the capacitor, only the time of day is lost.
The rest of the programming is stored in the memory and will not need to be reprogrammed. When the power is restored, the clock will
restart at 8 AM and will need to be reset.
Regeneration
Once an immediate regeneration is requested, a complete regeneration must occur to clear the request. Once the regeneration starts,
it must finish or the computer board will not clear. Manually walk (scroll) the control through regeneration to clear the computer board.
If the regeneration is aborted and the request is not cleared, another immediate regeneration will occur.
High-Speed Motor Operation in the Regeneration Mode
High-speed motor operation is achieved while stepping the control through the regeneration cycle. Pressing the scroll button a second
time, while in regeneration, activates the higher speed.
14 •
IRON & MANGANESE FILTER SYSTEM COMBO
12
7
6
4.5
17
17
17
17