Mitsubishi Electric CRHV-P600YA-HPB Service Handbook page 121

Hot water heat pump
Table of Contents

Advertisement

[ IX Troubleshooting ]
Sensors and item code list
Item
MAIN circuit
Error history 1
Error history 1 details (Inverter error)
Error history 1/Occurrence time
Error history 2
Error history 2 details (Inverter error)
Error history 2/Occurrence time
Error history 3
Error history 3 details (Inverter error)
Error history 3/Occurrence time
Error history 4
Error history 4 details (Inverter error)
Error history 4/Occurrence time
Error history 5
Error history 5 details (Inverter error)
Error history 5/Occurrence time
Error history 6
Error history 6 details (Inverter error)
Error history 6/Occurrence time
Inlet water temp (Twi )
Outlet water temperature (Two)
Discharge refrigerant 1 TH1
Suction refrigerant 1 TH2
Shell temperature 1 TH3
Heat exchanger wall temp. 1 TH4
Outdoor temp. TH9 or 4-20 mA or IT
Inlet water temperature 1 TH11
Outlet water temperature 1 TH12 Outlet water temperature 2 TH18
Representative water temperature 1 TH15
Representative water temperature 2 TH16
High pressure 1 HP1
Low pressure 1 LP1
Heatsink temperature(THHS)
Water temperature setting using an external
analog input (4-20 mA Current input)
I u(U-phase current)(Compressor)
I w(W-phase current)(Compressor)
I dc(Bus current)(Compressor)
Vdc(Bus voltage)(Compressor)
Suction SH (target)
Compressor frequency (actual frequency)
Suction SH
Shell bottom SH
Opening of the LEV on the main circuit
Injection LEV opening
Discharge SH (target)
Discharge SH
Target water temperature
4-20 mA (2) current
Water temperature setting using an external analog input (0-10 V or 2-10 V Voltage input)
Water temperature setting using an external analog input (1-5 V Voltage input)
Heat source inlet temperature 1 TH13 *1
Heat source outlet temperature 1 TH14/Heat source outlet temperature 2 TH20
*1 Under the standard pipe connection of the heat source. (Counter flow)
(Note1) Refer to the section "1. Checking the error history" for further information. (Page 111)
(Note2) Codes c01 through c11,c14,c37 and c38 indicate temperature sensors.
(Note3) Codes c12 and c13 indicate pressure sensors.
(Note4) Codes c15 through c18 indicate current sensors.
(Note5) Codes c19 indicate voltage sensor.
(Note6) Codes c24, c31, and c33 indicate target values.
(Note7) Code c25 indicates compressor's operating frequency.
(Note8) Code c26 indicates superheat that was calculated based on the low pressure and suction refrigerant temperature.
(Note9) Code c27 indicates superheat that was calculated based on the low pressure and shell temperature.
(Note10) Codes c29 and c30 indicate the degree of LEV opening.
(Note11) Code c32 indicates superheat that was calculated based on high pressure and discharge refrigerant temperature.
(Note12) When the input type is selected. When the input type is not selected = 0.
(Note13) c34,c35 and c36 show the external analog input values (water temperature settings)
(Note14) Effective when the value for item code 1080 is a value other than 0
HWE1312A
Item
code
SUB circuit
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
Inlet water temp 2 TH17
c01
c02
Discharge refrigerant 2 TH5
c03
Suction refrigerant 2 TH6
c04
Shell temperature 2 TH7
c05
Heat exchanger wall temp. 2 TH8
c06
-
c07
Inlet water temperature 2 TH17
c08
c09
-
c10
-
c11
High pressure 2 HP2
c12
Low pressure 2 LP2
c13
c14
-
c15
c16
c17
c18
c19
c24
c25
c26
c27
c29
c30
c31
c32
c33
c34
c35
c36
c37
*1
c38
Unit and circuit type
LED display
Main unit
MAIN circuit SUB circuit MAIN circuit SUB circuit
Error Code
Error Code
Time
Error Code
Error Code
Time
Error Code
Error Code
Time
Error Code
Error Code
Time
Error Code
Error Code
Time
Error Code
Error Code
Time
First decimal place
First decimal place
First decimal place
First decimal place
First decimal place
First decimal place
(Note14)
First decimal place
First decimal place
First decimal place
First decimal place
Fixed to 0 Fixed to 0 Fixed to 0
First decimal place
Fixed to 0 Fixed to 0 Fixed to 0
Second decimal place
Second decimal place
First decimal place
First decimal place (Note13)
Fixed to 0 Fixed to 0 Fixed to 0
First decimal place
First decimal place
First decimal place
Integer
First decimal place
Integer
First decimal place
First decimal place
Integer
Integer
First decimal place
First decimal place
First decimal place
First decimal place
Fixed to 0 Fixed to 0 Fixed to 0
First decimal place (Note12) Fixed to 0 Fixed to 0 Fixed to 0
First decimal place
(Note12) Fixed to 0 Fixed to 0 Fixed to 0
First decimal place
First decimal place
- 114 -
Sub unit
Notes
(Note1)
(Note2)
(Note2)
(Note2)
(Note2)
(Note2)
(Note2)
-
-
-
(Note2)
(Note2)
(Note2)
(Note2)
(Note2)
(Note3)
(Note3)
(Note2)
(Note4)
(Note4)
(Note4)
(Note4)
(Note5)
(Note6)
(Note7)
(Note8)
(Note9)
(Note10)
(Note10)
(Note6)
(Note11)
(Note6)
(Note13)
(Note13)
(Note13)
(Note2)
(Note2)
GB