Error history item list
Item
Error history 1
Error history 1 details (Inverter error)
Error history 1/Occurrence time
Error history 2
Error history 2 details (Inverter error)
Error history 2/Occurrence time
Error history 3
Error history 3 details (Inverter error)
Error history 3/Occurrence time
Error history 4
Error history 4 details (Inverter error)
Error history 4/Occurrence time
Error history 5
Error history 5 details (Inverter error)
Error history 5/Occurrence time
Error history 6
Error history 6 details (Inverter error)
Error history 6/Occurrence time
Inlet water temp (Twi ) (* Sub circuit: TH17)
Outlet water temperature (Two)
Discharge refrigerant temperature 1 TH1 / Discharge refrigerant temperature 2 TH5
Suction refrigerant temperature 1 TH2 / Suction refrigerant temperature 2 TH6
Shell temperature 1 TH3 / Shell temperature 2 TH7
Heat exchanger wall temperature 1 TH4 /
Heat exchanger wall temperature 2 TH8
Outdoor temperature TH9 or 4-20 mA or IT
Inlet water temperature 1 TH11 / Inlet water temperature 2 TH17
Outlet water temperature 1 TH12 / Outlet water temperature 2 TH18
Representative water temperature 1 TH15
Representative water temperature 2 TH16
High pressure 1 HP1 / High pressure 2 HP2
Low pressure 1 LP1 / Low pressure 2 LP2
Heatsink temperature (THHS)
Water temperature setting using an external analog input (4-20 mA Current input)
I u(U-phase current)(Compressor)
I w(W-phase current)(Compressor)
I dc(Bus current)(Compressor)
Vdc(Bus voltage)(Compressor)
Suction SH (target)
Compressor frequency (actual frequency)
Suction SH
Shell bottom SH
Opening of the LEV on the main circuit
Injection LEV opening
Discharge SH (target)
Discharge SH
4-20 mA (2) current
Target water temperature
Water temperature setting using an external analog input (0-10 V or 2-10 V Voltage input)
Water temperature setting using an external analog input (1-5 V Voltage input)
Heat source inlet temperature 1 TH13 *1
Heat source outlet temperature 1 TH14/Heat source outlet temperature 2 TH20
*1 Under the standard pipe connection of the heat source. (Counter flow)
(Note1) Item codes 1 through 18 indicate error histories. Each history has the error code, error detail code, and time as a set.
(Note2) Error histories are displayed from the newest to the oldest. (Each history has the error code, error detail code, and time as a set.)
Up to the past six histories can be displayed. (The older ones will be deleted.)
(Note3) If the error history is empty, "----" will blink.
(Note4) Refer to section "2. Checking the sensor status" for details. (page 113)
(Note5) When the input type is selected
When the input type is not selected = 0
(Note6) Effective when the value for item code 1080 is a value other than 0
HWE1312A
Item
LED display
code
MAIN circuit SUB circuit MAIN circuit SUB circuit
1
Error Code
2
Error Code
3
Time
4
Error Code
5
Error Code
6
Time
7
Error Code
8
Error Code
9
Time
10
Error Code
11
Error Code
12
Time
13
Error Code
14
Error Code
15
Time
16
Error Code
17
Error Code
18
Time
c01
First decimal place
c02
First decimal place
c03
First decimal place
c04
First decimal place
c05
First decimal place
c06
First decimal place
c07
First decimal place
(Note6)
c08
First decimal place
c09
First decimal place
c10
First decimal place
c11
First decimal place
c12
Second decimal place
c13
Second decimal place
c14
First decimal place
c15
First decimal place
(Note5)
c16
First decimal place
c17
First decimal place
c18
First decimal place
c19
Integer
c24
First decimal place
c25
Integer
c26
First decimal place
c27
First decimal place
c29
Integer
c30
Integer
c31
First decimal place
c32
First decimal place
c34
First decimal place
First decimal place
c33
(Note5)
First decimal place
c35
First decimal place
(Note5)
c36
c37
First decimal place
c38
First decimal place
- 112 -
Unit and circuit type
Main unit
Sub unit
-
-
-
Fixed to 0
Fixed to 0
Fixed to 0
Fixed to 0
Fixed to 0
Fixed to 0
Fixed to 0
Fixed to 0
Fixed to 0
Fixed to 0 Fixed to 0 Fixed to 0
Fixed to 0
Fixed to 0
Fixed to 0
Fixed to 0
Fixed to 0
Fixed to 0
Notes
(Note1)
(Note2)
(Note3)
(Note4)
GB

Advertisement

Table of Contents
loading

Table of Contents