ELECTRICAL / GAS CONNECTIONS

STEP 5:
ELECTRICAL CONNECTIONS
Wok Power Requirements
■ 120 VAC, 60Hz, single phase 15 Amp circuit.
Always disconnect electric supply cord from the
wall out or service disconnect before servicing
this appliance. Observe all governing codes and
ordinances when grounding, in absence of
which, observe National Electrical Code ANSI /
NFPA No. 70-1990
RECOMMENDED GROUNDING METHOD
This appliance is factory equipped with a power
supply cord with a three-prong grounding plug
(with polarized parallel blades). It must be plugged into a mating grounding type receptacle connected
to a correctly polarized 120 Volt circuit. If the circuit does not have a grounding type receptacle, it is the
responsibility and obligation of the installer to have the existing receptacle changed to a properly
grounded and polarized receptacle in accordance with all applicable local codes and ordinances by a
qualified electrician. In the absence of local codes and ordinances, the receptacle replacement shall be
in accordance with the National Electrical Code.
■ The third prong should not, under ANY circumstances, be cut or removed.

GAS REQUIREMENTS

Verify the type of gas supplied to the location. The wok is shipped from the factory set up and adjusted
for natural gas or LP (propane), depending on specific model ordered.
Conversion of gas from LP to
NG or NG to LP is not permissible.
NATURAL GAS
■ Connection: 1/2" N.P.T., Minimum 5/8" dia flex line ■ Supply Pressure: 6" to 9" W.C.
LP GAS
■ Connection: 1/2" N.P.T., Minimum 5/8 dia. Flex line. ■ Supply Pressure: 11" to 14" W.C.
A regulator is required at the LP source to provide a maximum of 14"W.C. to the wok regulator.