backguard installation

Fig. 6
Fig. 7
GAS REQUIREMENTS
Verify the type of gas supplied to the location. The
cooktop is shipped from the factory set up and adjusted
for natural gas or LP (propane), depending on specific
model ordered. The unit cannot be converted.
NATURAL GAS
Connection: 1/2" N.P.T., Minimum 5/8" dia flex line
Pressure: 6" to 14" W.C.
6
STEP 4:
BACKGUARD KITS:
The backguard is located as shown in Fig. 6.
Secure the backguard to the wall behind the cooktop.
Specific instructions for installation of the High Shelf or
Low Backguards can be found packaged with
the backguard. See also page 5.
The backguard must be installed when
there is less than a 12" clearance between
combustibles and the back of the cooktop
(above the cooking surface.
STEP 5:
ELECTRICAL CONNECTIONS
Power requirements Cooktop
120 VAC, 60Hz., single phase 15 Amp circuit.
Always disconnect electric supply cord from the wall out
or service disconnect before servicing this appliance.
Observe all governing codes and ordinances when
grounding, in absence of which, observe National
Electrical Code ANSI / NFPA No. 70-1990
RECOMMENDED GROUNDING METHOD
This appliance is factory equipped with a power
supply cord with a three-prong grounding plug (with
polarized parallel blades). It must be plugged into
a mating grounding type receptacle connected to
a correctly polarized 120 Volt circuit. If the circuit
does not have a grounding type receptacle, it is the
responsibility and obligation of the installer to have the
existing receptacle changed to a properly grounded and
polarized receptacle in accordance with all applicable
local codes and ordinances by a qualified electrician.
In the absence of local codes and ordinances, the
receptacle replacement shall be in accordance with
the National Electrical Code.
The third prong should not, under ANY
circumstances, be cut or removed.
LP GAS
Connection: 1/2" N.P.T., Minimum 5/8 dia. Flex line.
Pressure: 11" to 14" W.C.
A regulator is required at the LP source to provide a
maximum of 14"W.C. to the cooktop regulator.