24
4.2

CHANGING A TOP VENT TO A REAR VENT

In order to convert the venting confi guration from a top exit to a rear exit, remove components as illustrated.
When reinstalling in the alternate position: Check gaskets for tears, replace if necessary to ensure a proper
EN
seal.
Outer Top
Top Heat
Shield
7" (178mm)
Collar
7" (178mm)
Gasket
4" (102mm)
Collar
4" (102mm)
Gasket
W415-1328 / A / 01.05.16
4" (102mm)
Cover Plate
4" (102mm)
Gasket
Optional trivet required when converting
to rear exit.
7" (178mm)
Cover Plate
7" (178mm) Gasket