Figure 5-3 Menu 2.1 Advanced Wan Setup; Table 5-3 Advanced Wan Port Setup: At Commands Fields - ZyXEL Communications 10 User Manual

Internet security gateway
Hide thumbs Also See for 10:
Table of Contents

Advertisement

AT Command Strings:
Drop DTR When Hang Up= Yes
AT Response Strings:
The following table describes fields in this menu.

Table 5-3 Advanced WAN Port Setup: AT Commands Fields

FIELD
AT Command
Strings:
Dial Enter the AT Command string to make a call.
Drop Enter the AT Command string to drop a call. "~" represents a one
Answer Enter the AT Command string to answer a call.
Drop DTR When
Hang Up
AT Response String:
CLID (Calling Line
Identification)
WAN and Dial Backup Setup
Menu 2.1 - Advanced WAN Setup
Dial= atdt
Drop= ~~+++~~ath
Answer= ata
CLID= NMBR =
Called Id=
Speed= CONNECT

Figure 5-3 Menu 2.1 Advanced WAN Setup

second wait, e.g., "~~~+++~~ath" can be used if your modem has a
slow response time.
Press the [SPACE BAR] to choose either
is selected (the default), the DTR (Data Terminal Ready) signal is
dropped after the "AT Command String: Drop" is sent out.
Enter the keyword that precedes the CLID (Calling Line Identification)
in the AT response string. This lets the ZyWALL capture the CLID in
the AT response string that comes from the WAN device. CLID is
required for CLID authentication.
ZyWALL 10~100 Series Internet Security Gateway
Call Control:
Dial Timeout(sec)= 60
Retry Count= 0
Retry Interval(sec)= N/A
Drop Timeout(sec)= 20
Call Back Delay(sec)= 15
DESCRIPTION
Yes or No. When Yes
DEFAULT
atdt
+++ath
ata
Yes
NMBR =
5-5

Advertisement

Table of Contents
loading

This manual is also suitable for:

Zywall 10Zywall 10wZywall 50Zywall 100

Table of Contents