Sit Proflame 2 Electronic Ignition - Montigo H Series Installation & Maintenance Manual

Pier, bay & corner
Table of Contents

Advertisement

1.
stoP! Read the safety information above on this label.
2.
Remove the lower horizontal access panel.
3.
Turn "ON" manual "ON/OFF" switch located below the horizontal access
panel (if available).
4.
turn Incoming gas valve to the on" position.
5.
wait 5 minutes to clear out any gas. If you smell gas, stoP! Follow "b" in the
safety information above on this label. If you don't smell gas, go to the next
step.
SW1
LED1
LED2
sw1 = Programing button
led1 = Red diagnostic light
led2 = Amber Programing Remote control light
1.
Turn off fireplace using wall switch or remote control.
2.
Remove the lower horizontal access panel.
xg0227 - 112718

SIT Proflame 2 Electronic Ignition

For Your Safety - READ BEFORE LIGHTING:
with American Flame Electronic Ignition
Main
On/Off
Switch
Main
Switch
harness
sensor
Stepper
Ignitor
motor
Power
3.15A
Fuse
To Turn Off Gas To Appliance:
6.
Turn fireplace "ON" using wall switch or remote control.
7.
If the Fireplace does not light, the System will cycle through two trials, (one
minute audible clicking, thirty seconds of silence, and then another one
minute of audible clicking). If the system locks out due to inadequate gas
flow, refer to "Troubleshooting" in instruction guide.
8.
After completion of the information in the troubleshooting section, Repeat
step 5.
9.
If the system will not function correctly, follow the instructions "To Turn Off
gas to Appliance" and call your service technician or gas supplier.
Manifold Pressure
MAnIFold PRessuRe test
Test Connection
connectIon
Inlet PRessuRe
Inlet Pressure
Test Connection
3.
Turn the incoming gas control valve to "Off".
4.
Replace the lower horizontal access panel.
Operation
Pilot Adjustment Screw
PIlot AdJustMent scRew
31

Advertisement

Table of Contents
loading

Table of Contents